Título : Determination of heat transfer coefficients in plastic French straws plunged in liquid nitrogen
Autor : Santos, María Victoria 
Sansiñena, Marina Julia 
Chirife, Jorge 
Zaritzky, Noemí 
Otros colaboradores: Universidad Nacional de La Plata (Argentina). Facultad de Ingeniería. Departamento de Ingeniería Química
Consejo Nacional de Investigaciones Científicas y Técnicas (Argentina) ; Universidad Nacional de la Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos
Universidad Católica Argentina (Buenos Aires). Facultad de Ciencias Agrarias
Palabras clave : TRANSFERENCIA DE CALORNITROGENO LIQUIDOCONGELACIONREFRIGERACIONMETODO DE ELEMENTOS FINITOSEBULLICIONCRIOPRESERVACION
Fecha de publicación : 2014
Cita : Santos, M.V.; M. Sansiñena; J. Chirife y N. Zaritzky. 2014. Determination of heat transfer coefficients in plastic French straws plunged in liquid nitrogen [en línea]. Preprint del artículo publicado en Cryobiology 69(3). Disponible en: https://repositorio.uca.edu.ar/handle/123456789/5457
Resumen : Abstract: The knowledge of the thermodynamic process during the cooling of reproductive biological systems is important to assess and optimize the cryopreservation procedures. The time temperature curve of a sample immersed in liquid nitrogen enables the calculation of cooling rates and helps to determine whether it is vitrified or undergoes phase change transition. When dealing with cryogenic liquids, the temperature difference between the solid and the sample is high enough to cause boiling of the liquid, and the sample can undergo different regimes such as film and/or nucleate pool boiling. In the present work, the surface heat transfer coefficients (h) for plastic French straws plunged in liquid nitrogen were determined using the measurement of time-temperature curves. When straws filled with ice were used the cooling curve showed an abrupt slope change which was attributed to the transition of film into nucleate pool boiling regime. The h value that fitted each stage of the cooling process was calculated using a numerical finite element program that solves the heat transfer partial differential equation under transient conditions. In the cooling process corresponding to film boiling regime, the h that best fitted experimental results was h=148.12 ± 5.4 W/m2 K and for nucleate-boiling h=1355 ± 51 W/m2 K. These values were further validated by predicting the time-temperature curve for French straws filled with a biological fluid system (bovine semen-extender) which undergoes freezing. Good agreement was obtained between the experimental and predicted temperature profiles, further confirming the accuracy of the h values previously determined for the ice-filled straw. These coefficients were corroborated using literature correlations. The determination of the boiling regimes that govern the cooling process when plunging straws in liquid nitrogen constitutes an important issue when trying to optimize cryopreservation procedures. Furthermore, this information can lead to improvements in the design of cooling devices in the cryobiology field
URI : https://repositorio.uca.edu.ar/handle/123456789/5457
Disciplina: PRODUCCION AGROPECUARIA
Derechos: Acceso Abierto
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato
determination-heat-transfer-coefficients.pdf653,67 kBAdobe PDFVista previa
Visualizar/Abrir
Mostrar el registro Dublin Core completo del ítem

Visualizaciones de página(s)

182
comprobado en 18-abr-2024

Descarga(s)

247
comprobado en 18-abr-2024

Google ScholarTM

Consultar



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons