Please use this identifier to cite or link to this item:
https://repositorio.uca.edu.ar/handle/123456789/12502
Título : | All polarization-maintaining passively modelocked ytterbium-doped fiber lasers, behavior under two different cavity configurations | Autor : | Cuadrado-Laborde, Christian Carrascosa, Antonio Diez, Antonio Cruz, J. L. Andrés, M. V. |
Palabras clave : | LASER; FISICA; ITERBIO; FIBRAS DE CRISTAL FOTONICO | Fecha de publicación : | 2020 | Editorial : | Taylor & Francos | Cita : | Cuadrado-Laborde, C., et al. All polarization-maintaining passively modelocked ytterbium-doped fiber lasers, behavior under two different cavity configurations [en línea]. Fiber and Integrated Optics. 2020, 39(5-6) doi:10.1080/01468030.2020.1846097 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/12502 | Resumen : | Abstract: In this work, we review our recent investigations on the behavior of a polarization-maintaining passively mode-locked ytterbium-doped laser in two different cavity configurations, namely: fiber-ring (FR) and Fabry-Perot (FP). Opposed to standard configurations that rely on the use of strong filtering within the cavity by including an ad hoc component with this purpose, here the filtering action is solely performed by the spectral overlapping of the different components within the fiber lasers. We found that the lack of a specific filter within the cavity does not deteriorate the performance as compared with previous works. We also report the changes in the output light pulses when the net dispersion of the cavity was varied. Additionally, different lengths of an ad hoc anomalous polarization-maintaining (PM) photonic crystal fiber (PCF) were used as intracavity dispersion compensator, to shift the operation of the laser from net-normal to the net-anomalous regime. The shortest output light pulses [6 ps (FR) and 8 ps (FP)] were obtained when the net-cavity dispersion approached zero. Since the obtained light pulses were far to be transform-limited, we also discuss the possibility of out-of-cavity recompression by using the same PM-PCF mentioned above. After recompression, pulse widths of 3 ps were obtained, limited by the available length of PM PCF. | URI : | https://repositorio.uca.edu.ar/handle/123456789/12502 | ISSN : | 0146-8030 1096-4681 (Online) |
Disciplina: | INGENIERIA | DOI: | 10.1080/01468030.2020.1846097 | Derechos: | Acceso abierto |
Appears in Collections: | Artículos |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
all-polarization-maintaining.pdf | 383,73 kB | Adobe PDF | View/Open |
Page view(s)
54
checked on Apr 27, 2024
Download(s)
228
checked on Apr 27, 2024
Google ScholarTM
Check
Altmetric
This item is licensed under a Creative Commons License