Por favor, use este identificador para citar o enlazar este ítem:
https://repositorio.uca.edu.ar/handle/123456789/5593
Título: | Force plate calibration and setup for assessments of human balance | Autor: | Ghersi, Ignacio Castro Arenas, Cristhian Borsoi, P. D. Miralles, Mónica Teresita |
Palabras clave: | BIOMECANICA; FUNCIONES MOTORAS; EQUILIBRIO; INSTRUMENTOS DE MEDICION; CALIBRACION; MOTRICIDAD | Fecha de publicación: | 2017 | Editorial: | Springer | Cita: | Ghersi I., Castro Arenas C.F., Borsoi P.D., Miralles M.T. Force plate calibration and setup for assessments of human balance [en línea]. En: Torres I., Bustamante J., Sierra D. (eds) VII Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Santander, Colombia, October 26th-28th, 2016. IFMBE Proceedings, vol 60. Springer, Singapore: 2017. https://doi.org/10.1007/978-981-10-4086-3_50 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/5593 | Resumen: | Abstract: Repeatable, quantitative evaluations of human balance rely on thorough characterizations of the devices and sensors used in measurements. Given the growing concern on this field, the research group has developed dedicated devices for the assessment of gait and balance, including a force plate. In this work, a calibration procedure for this force plate is devised and implemented, based on a calibration device which combines versatility, ease of use, and low-cost, and on refer-ence weights. The procedure is detailed, and its results are shown, indicating a positive response for the device, and prov-ing a superior fit compared to the theoretical estimation of its behavior. Based on this improved knowledge on the designed force plate, a dedicated signal-analysis tool is shown, incorpo-rating calibration results and curves. Finally, examples of use of this tool are detailed, with standing balance registers from a control subject, indicating the resulting capabilities of the whole system as a promising tool for the assessment of human balance. | URI: | https://repositorio.uca.edu.ar/handle/123456789/5593 | ISBN: | 978-981-10-4086-3 (online) 978-981-10-4085-6 (impreso) |
Disciplina: | INGENIERIA | DOI: | 10.1007/978-981-10-4086-3_50 | Derechos: | Acceso abierto. 1 año de embargo | Fuente: | Torres I., Bustamante J., Sierra D. (eds) VII Latin American Congress on Biomedical Engineering CLAIB 2016, Bucaramanga, Santander, Colombia, October 26th-28th, 2016. IFMBE Proceedings, vol 60. Springer, Singapore: 2017 ISBN 978-981-10-4086-3 (online) ISBN 978-981-10-4085-6 (impreso) |
Aparece en las colecciones: | Ponencias |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
force-plate-calibrations-setup.jpg | 6,16 kB | JPEG | ![]() Visualizar/Abrir | |
force-plate-calibrations-setup.pdf | 662,85 kB | Adobe PDF | ![]() Visualizar/Abrir |
Visualizaciones de página(s)
184
comprobado en 30-abr-2024
Descarga(s)
508
comprobado en 30-abr-2024
Google ScholarTM
Ver en Google Scholar
Altmetric
Altmetric
Este ítem está sujeto a una Licencia Creative Commons